Peptide COA Results and Units Explained: %, ppm, EU/mg and Da

Most COA guides tell you which tests a report should include. This one is about the numbers themselves. A single peptide certificate of analysis can mix six different kinds of units on one page: percent by peak area, percent by weight, daltons, mass-to-charge ratios, parts per million and endotoxin units. Two of them even share the same abbreviation while meaning completely different things.

Read them correctly and a COA tells you exactly what is in a vial. Read them wrong and a 10 mg vial looks like 10 mg of peptide when it may hold closer to 8. This guide works through every unit you are likely to meet, with worked examples, an interactive sample COA and free calculators.

Try the interactive COATake the fake-COA challengeExplain your own COA

The short version
  • HPLC purity is a percentage of peak area, not of weight.
  • Net peptide content is a percentage of weight, and it is normally well below 100%.
  • For a label given in gross weight: full-length peptide (mg) ≈ label mg × net peptide content × HPLC purity.
  • Mass spec reports daltons (Da) or m/z, and one peptide shows several m/z values, one per charge state.
  • ppm means micrograms per gram on an impurity test, but a relative mass error on a mass spec report.
  • Endotoxin is reported in EU/mg, and a result such as “< 0.5” means below the test’s reporting limit.

Every unit on a peptide COA, at a glance

Not every COA reports every test below. Standard research-grade reports usually cover appearance, HPLC purity and mass spec identity, and more complete reports add the rest. Use this table as a key.

TestUnit you will seeWhat it measuresExample result
AppearanceDescriptionVisual check of the powder or cakeWhite to off-white lyophilized powder
Purity (RP-HPLC)% (peak area)Share of the UV signal that sits in the main peak98.6%
Identity (mass spec)Da, g/mol or m/zMolecular mass of the main component1418.71 Da (theory 1418.70)
Net peptide content% w/wShare of the powder’s weight that is peptide80.4%
Water (Karl Fischer)% w/wWater held in the powder5.2%
Counter-ion (TFA or acetate)% w/wAcid bound to the peptide as a salt11.8%
Residual solvents (GC)ppm (µg/g)Solvents left over from synthesis and purificationAcetonitrile 120 ppm
Elemental impurities (ICP-MS)ppm or ppbMetals such as lead, arsenic and mercuryPb < 0.5 ppm
Bacterial endotoxin (LAL)EU/mgEndotoxin from Gram-negative bacteria< 0.5 EU/mg
Microbial limitsCFU/gViable bacteria, yeast and mold< 10 CFU/g
Retention timeminWhen the main peak leaves the HPLC column12.4 min
Detection wavelengthnmUV wavelength used to measure purity214 nm

Example results are illustrative and do not describe any specific lot.

Try it: an interactive sample COA

Here is a sample peptide COA laid out the way accredited laboratories format real reports: lab details and accreditation, sample identifiers, a results table with methods and specifications, the chromatogram and mass spectrum, detection limits, a two-person sign-off and document control. Tap any part of it to see what it means. Then switch to Spot the red flags, where a second version hides seven problems that turn up on unreliable reports. For the full two-round version with 15 red flags and a printable checklist, try Spot the Fake COA.

Your vial · compare it with the reportBPC-157 · 10 mg · lyophilizedLot BPC-2611-01
PDF COA_2611-0457.pdf · digitally signed by the laboratory1 / 1  ·  100%
AMPLEANALYTICAL LABORATORYIndependent peptide testing
Example Analytical Laboratory
123 Sample Way, Suite 100
Anytown, USA 00000
www.example.com · info@example.com
(555) 010-0199
SAMPLEIllustrative example · not a real lot
Certificate of Analysis
ClientExample Customer
Accession #2611-0457
Search codeEXC-2611-0457
Received11/03/2026
Tested11/04/2026
LotBPC-2611-01
ConditionIntact, ambient
Revision0 (original issue)
Sample summary
G2 MEDS BPC-157 10 mg vialSample as received
Product
BPC-157GEPPPGKPADDAGLV
Label claim
10 mg per vial (gross weight)
Identity (LC-MS)
Confirmed (both vials)
Purity (HPLC)
98.6% ± 0.3%
Peptide per vial
8.04 mg · 8.11 mgVial 1 · Vial 2 (80.4% w/w)
Appearance
White lyophilized powder
Endotoxin (LAL)
< 0.5 EU/mg
Final disposition
PASS
Analytical results

Methods: reversed-phase HPLC with UV detection; identity by electrospray mass spectrometry (LC-MS); water by Karl Fischer; residual solvents by headspace GC; endotoxin by LAL. References: USP <85> (bacterial endotoxins), USP <921> (water determination), ICH Q3C (residual solvents).

TestMethodMethod IDSpecificationResultDisposition
AppearanceVisualQC-VIS-001White to off-white lyophilized powderConformsPass
IdentityESI-MSQC-MS-0071418.70 ± 0.50 Da (monoisotopic)1418.71 DaPass
PurityRP-HPLC, UV 214 nmQC-HPLC-014≥ 98.0% (area)98.6%Pass
Net peptide contentAmino acid analysisQC-AAA-003Report80.4% w/w—
WaterKarl FischerQC-KF-002≤ 8.0% w/w5.2% w/wPass
Counter-ion (TFA)Ion chromatographyQC-IC-005Report11.8% w/w—
Residual acetonitrileHeadspace GCQC-GC-009≤ 410 ppm120 ppmPass
Bacterial endotoxinLAL, kinetic chromogenicQC-LAL-004Report< 0.5 EU/mg—

Swipe the table sideways to see every column.

Notes: ND = not detected (< LOD) · < LOQ = below limit of quantitation · 1% = 10 mg/g = 10,000 ppm
Raw data
Figure 1. HPLC chromatogram (UV 214 nm)
12.40 810121416 min mAU, UV 214 nm
PeakRT (min)Area %
110.900.30
211.850.80
312.4098.60
412.950.20
513.700.10
Figure 2. ESI-MS spectrum (positive mode)
473.913+710.362+1419.711+40080012001600 m/z Rel. intensity
Ionm/zCharge
[M+3H]3+473.913+
[M+2H]2+710.362+
[M+H]+1419.711+
Performed by/Date:Alex AnalystDigitally signed by Alex Analyst
Date: 2026.11.04 16:42:10 -05’00’
Checked by/Date:Quinn ReviewerDigitally signed by Quinn Reviewer
Date: 2026.11.05 09:18:52 -05’00’

Notes: This certificate of analysis reflects only the sample indicated on this form, as received by the laboratory in good condition. This report may not be reproduced except in full. For research use only.

Accreditation shown on the original report
ISO/IEC 17025 accredited testing laboratory
Verify this report
www.example.com/verify
Search code EXC-2611-0457
Form QC-012 | Rev 03 | Page 1 of 1 | Results relate only to the sample as received.

Want it on paper? Download the sample as a two-page PDF with a one-page reading guide. Or upload your own COA and get every line explained the same way, with the math checked for you.

Sample peptide COA (PDF)The full two-page BPC-157 sample report, plus a one-page guide to every section. 3 pages.Edition Nov 16, 2026 · 656 KBDownload

Free to print and share for education. All data is illustrative and comes from a fictional laboratory.

The laboratory, lot and results on this sample report are fictional and for illustration only.

How to read one row: specification, result, method

A well-built COA lays each test out as a row with three or four columns. Reading them in order prevents most mistakes.

  • Specification is the acceptance limit set before testing, such as “≥ 98.0%” or “Conforms to structure”. “Report” or “For information” means no limit was set and the value is simply recorded.
  • Result is what the laboratory measured on this lot.
  • Method names the technique or standard, for example RP-HPLC, ESI-MS, Karl Fischer or USP <85>. Without it, a number cannot be checked or compared.
  • Conclusion says whether the result met the specification: Pass, Conforms or Complies.

Symbols that change the meaning of a number

You seeIt means
< 0.5Below the method’s reporting or quantitation limit. The true value is somewhere under 0.5; it is not a measurement of 0.5.
NDNot detected. A complete report also states the detection limit, because “not detected” only means something relative to how sensitive the test was.
< LOQBelow the limit of quantitation: possibly present, but too low to put a reliable number on.
≥ 98.0%Usually a specification: the result must be at least 98.0%.
ConformsThe result matched a qualitative specification, such as an expected mass or appearance.

A practical consequence: a lab that reports endotoxin as “< 0.05 EU/mg” has run a more sensitive test than one that reports “< 1 EU/mg”, even though both are passing results.

“Percent” is not one unit: % area vs. % w/w

This is the single most common misreading of a peptide COA. The percentages on the page come in two families that answer different questions.

Percent by peak areaPercent by weight (w/w)
Used forHPLC purityNet peptide content, water, counter-ion
Question it answersOf the material the UV detector can see, how much is the main peak?Of the powder on the balance, what share is this component?
What it cannot seeWater, salts and anything that does not absorb at the detection wavelengthWhich peptide species are present

Because the two families measure different things, a powder can be 99% pure by HPLC and only 75% peptide by weight, and both numbers can be correct at the same time. HPLC purity tells you the peptide is the right one; net peptide content tells you how much of the powder is peptide at all. For more on the separation itself, see HPLC purity vs. mass spec.

Gross weight, net peptide content and the real milligrams in a vial

Unless a supplier states otherwise, peptides are normally supplied by gross weight: the weight of the lyophilized powder, which includes the peptide plus bound water, counter-ions and traces of solvent. Net weight counts only the peptide. Net peptide content (NPC) is the ratio between the two, and laboratories usually measure it by quantitative amino acid analysis or by elemental (CHN) nitrogen analysis.

Why net peptide content is lower than you might expect

  • Counter-ions. Peptides purified by reversed-phase HPLC with trifluoroacetic acid are recovered as TFA salts. Each positively charged site, such as the N-terminus and lysine, arginine or histidine side chains, can hold a trifluoroacetate ion weighing 114.02 g/mol.
  • Water. Lyophilized peptides are hygroscopic and hold water even after freeze-drying.
  • Sequence. Peptides with many basic residues carry more counter-ions, so their net content tends to be lower.

One peptide manufacturer notes that a lyophilized sample can contain 10 to 70 percent non-peptide material by weight, so an NPC well below 100% is normal and not a sign of a bad batch.

Worked illustration: BPC-157 as a TFA salt

BPC-157 is a 15-residue peptide with the formula C62H98N16O22 and an average molecular weight of 1419.56 g/mol. It has two basic sites, the N-terminal amine and one lysine. If both carry a trifluoroacetate ion, the salt weighs 1419.56 + (2 × 114.02) = 1647.60 g/mol, and the peptide makes up only 86.2% of that weight before any water is counted. Add around 5% water and the net peptide content falls to roughly 82%. Real values depend on the exact salt form and drying, which is why they are measured rather than assumed.

The formula

Full-length target peptide (mg) = label amount (mg) × net peptide content × HPLC purity
Enter both percentages as decimals. Use this when the label amount is gross powder weight. If the COA states that the label amount is net peptide, multiply by HPLC purity only.

Both factors are needed because net peptide content counts all peptide material, including closely related impurities such as truncated sequences, while HPLC purity tells you what share of that peptide material is the full-length target.

StepValueRunning total
Label amount (gross)10.00 mg10.00 mg of powder
× Net peptide content80.0%8.00 mg of peptide material
× HPLC purity98.6%7.89 mg of full-length peptide
Non-peptide mass (water, counter-ions)2.00 mg
Related peptide impurities0.11 mg

Worked example with illustrative numbers. Use the toolkit below to run your own COA values.

A quick sanity check: the sum test

When a COA reports net peptide content, water, counter-ion and residual solvents, those weight percentages should add up to roughly 100%, give or take a few percent for method uncertainty. A report showing 95% net peptide, 8% water and 12% TFA adds up to 115%, which is physically impossible. It usually means the values came from different lots or one of them is wrong.

Net peptide content also matters any time you make a solution of known concentration. The G2 MEDS concentration calculator accepts it as an input.

Mass spec units: daltons, m/z and charge states

Mass spectrometry confirms identity by measuring mass. Three ideas make its numbers readable. To get the expected mass and m/z values for any sequence, use our peptide molecular weight calculator.

Daltons and g/mol are numerically the same

One dalton (Da) is one unified atomic mass unit. For any molecule, the mass in daltons and the molar mass in g/mol are the same number, so “MW 1419.56 g/mol” and “1419.56 Da” describe the same thing. Larger molecules are often written in kilodaltons (kDa).

The instrument reports m/z, not mass

A mass spectrometer measures the mass-to-charge ratio, m/z, of ions. Electrospray ionization (ESI) adds protons to a peptide, often more than one, so the same molecule appears at several m/z values. For a peptide of neutral mass M carrying z extra protons:

m/z = (M + z × 1.00728) ÷ z
1.00728 Da is the mass of a proton.

For BPC-157 that gives the following expected ions:

IonCharge (z)Monoisotopic m/zAverage m/z
[M+H]+11419.71141420.56
[M+2H]2+2710.3594710.79
[M+3H]3+3473.9087474.19

Calculated from C62H98N16O22: monoisotopic mass 1418.70416 Da, average mass 1419.56 Da.

So a spectrum whose tallest peak sits near 710.4 is fully consistent with a 1418.7 Da peptide. It is the doubly charged ion, not a different compound. MALDI-TOF, the other common technique, mostly produces singly charged [M+H]+ ions, which is why MALDI and ESI reports for the same lot can look different.

Monoisotopic vs. average mass

The monoisotopic mass uses the most abundant isotope of each element (12C, 1H, 14N, 16O). The average mass uses the natural mix of isotopes. For BPC-157 they are 1418.70 and 1419.56 Da, about 0.85 Da apart. High-resolution instruments usually report monoisotopic values, and lower-resolution instruments often report average values. A good COA says which one it uses. Comparing a monoisotopic measurement to an average theoretical value creates an apparent error of nearly 1 Da that is not real.

Adducts are not impurities

Peptides also pick up sodium or potassium ions. An [M+Na]+ peak appears 21.98 Da above [M+H]+, and [M+K]+ appears 37.96 Da above it. These are common in electrospray spectra and do not mean the sample is the wrong compound.

Mass accuracy in ppm

High-resolution reports state how close the measured value is to the theoretical one as a mass error in parts per million:

Mass error (ppm) = (measured − theoretical) ÷ theoretical × 1,000,000
Example: [M+2H]2+ measured at 710.3610 against 710.3594 theoretical gives an error of +2.3 ppm.

High-resolution instruments often specify an accuracy of a few ppm. Lower-resolution instruments report mass to a tenth of a dalton or so and do not quote ppm at all, which is normal for routine identity checks.

ppm has two meanings on the same page

“ppm” appears in two unrelated places on a peptide COA, and mixing them up is easy.

Where it appearsWhat ppm meansExample
Residual solvents, elemental impuritiesConcentration: micrograms per gram of sample (µg/g, the same as mg/kg)410 ppm acetonitrile = 0.041% of the powder by weight
High-resolution mass specRelative error: millionths of the measured mass+2.3 ppm at m/z 710 = 0.0016 m/z units

Converting concentration units

UnitEquals
1% w/w10,000 ppm = 10 mg/g
1 ppm1 µg/g = 1 mg/kg = 0.0001%
1 ppb1 ng/g = 0.001 ppm

Residual solvents and the ICH Q3C benchmark

Solid-phase peptide synthesis and purification use solvents such as N,N-dimethylformamide (DMF), dichloromethane (DCM), acetonitrile and diethyl ether. Residual solvent tests, usually by headspace gas chromatography, report what is left in ppm. Finding some is normal: almost any purified material keeps a trace, so the real question is whether the amount is under the limit. The pharmaceutical guideline ICH Q3C sets concentration limits that many laboratories use as a yardstick even for research-grade material:

SolventICH Q3C classConcentration limit
AcetonitrileClass 2410 ppm
DichloromethaneClass 2600 ppm
N,N-DimethylformamideClass 2880 ppm
MethanolClass 23,000 ppm
Diethyl ether, ethanol, acetone, acetic acidClass 35,000 ppm (general limit)

ICH Q3C is written for pharmaceutical products. Research-grade COAs are not bound by it, but it is a useful reference point.

Trifluoroacetic acid is not reported this way. Because it is bound to the peptide as a counter-ion, it is normally reported as counter-ion content in % w/w.

Elemental impurities

Metals such as lead, arsenic, cadmium and mercury are measured by ICP-MS and reported in ppm (µg/g) or, for very low levels, ppb (ng/g). USP chapters <232> and <233> and ICH Q3D are the usual references.

EU/mg: endotoxin results

Endotoxin is lipopolysaccharide from the outer membrane of Gram-negative bacteria. It strongly stimulates immune cells in culture, so it can affect cell-based assays even when a peptide is chemically pure. That is why endotoxin is reported separately from purity.

  • It is measured with the Limulus amebocyte lysate (LAL) test described in USP <85>, using one of three techniques: gel-clot, turbidimetric or chromogenic.
  • Results are given in endotoxin units (EU). Under USP <85>, one USP endotoxin unit equals one international unit (IU) of endotoxin.
  • Limits can be expressed per mL, per mg or per unit of activity. For a powder, EU/mg is the natural unit.
  • A result written as “< 0.5 EU/mg” means the test detected nothing above that level at the dilution used.

Many research-grade COAs do not include endotoxin at all. That is not a red flag for chemistry work, but for cell-culture experiments it is worth asking for.

The smaller units: CFU/g, minutes and nanometers

  • CFU/g (colony-forming units per gram) comes from microbial limit tests and counts viable bacteria, yeast and mold.
  • Retention time (min) is when the main peak leaves the HPLC column. It depends on the column, gradient and instrument, so it is only meaningful against a reference run on the same method, never across laboratories. A retention time on its own does not prove identity.
  • Detection wavelength (nm) matters more than it looks. At 214 to 220 nm the detector sees the peptide bond itself, so nearly every peptide species shows up. At 280 nm the signal comes almost entirely from tryptophan and tyrosine side chains, so a purity measured at 280 nm can miss impurities that lack those residues. BPC-157 contains none of them, so a 280 nm purity figure for it would be meaningless.

Unit red flags

These problems show up in the units themselves, before you even look at the science. Pair this list with the broader COA reading guide.

  • Numbers with no units, or no method named for a result.
  • Net peptide content presented as “purity”, or purity given in % w/w.
  • Weight percentages that add up to well over 100%.
  • An observed m/z that does not match any charge state of the stated molecular weight. The calculator below checks this in seconds.
  • A mass spec result about 1 Da off with no statement of whether it is monoisotopic or average.
  • A measured mass identical to the theoretical value to four decimal places on every lot, which suggests a copied number rather than a measurement.
  • Endotoxin reported in ppm or percent instead of EU.
  • “< LOQ” or “ND” with no limit stated.
  • A purity figure measured at 280 nm for a peptide with no tryptophan or tyrosine.
  • Perfectly round results, such as 99.9% or 100.0%, on every product.

COA units toolkit

Three quick calculators for the arithmetic in this guide: the real peptide amount in a vial, the expected mass spec ions for any molecular weight, and ppm conversions.

1. How much peptide is really in the vial?

Enter the numbers from the label and the COA. Laboratory arithmetic only.

Enter the label amount and HPLC purity to see the estimate.

2. Mass spec ion checker

Enter the molecular weight from the COA or the theoretical mass of the sequence. Add a measured m/z to see the error in ppm.

Enter a molecular weight to see the expected ions.

3. ppm, %, mg/g converter

For concentration results such as residual solvents, water, alkaloids or elemental impurities. Not for mass-accuracy ppm.

Enter a value to convert it.

These tools do unit arithmetic on numbers you enter. They do not provide use, dosing or administration guidance. All G2 MEDS products are for in-vitro laboratory research only.

Frequently asked questions

What unit is peptide purity reported in?

Purity is reported as a percentage of peak area from reversed-phase HPLC, usually detected at 214 to 220 nm. It is the share of the detected UV signal that belongs to the main peak. It is not a percentage of the powder’s weight and does not account for water or counter-ions.

Is a 10 mg vial of peptide really 10 mg of peptide?

Usually not. Unless the supplier states otherwise, the label amount is normally the gross weight of the lyophilized powder, which includes bound water and counter-ions. Multiply the label amount by the net peptide content and the HPLC purity to estimate the full-length peptide. With 80% net content and 98.6% purity, a 10 mg vial holds about 7.9 mg.

What is a normal net peptide content?

There is no single normal value, because it depends on the sequence, the salt form and how dry the powder is. Values well below 100% are expected. One peptide manufacturer notes that a lyophilized sample can contain 10 to 70 percent non-peptide material by weight, mostly counter-ions and water.

Why is the mass spec result about half the molecular weight?

Electrospray mass spectrometry measures mass-to-charge ratio (m/z), and peptides often carry two or more protons. A doubly charged ion appears at roughly half the molecular weight. For BPC-157, with a monoisotopic mass of 1418.70 Da, the [M+2H]2+ ion appears at m/z 710.36.

What does ppm mean on a peptide COA?

It depends on the test. For residual solvents and elemental impurities, ppm is a concentration: micrograms per gram of sample, so 410 ppm is 0.041% by weight. On a high-resolution mass spec result, ppm is the relative error between the measured and theoretical mass.

What does a result of less than 0.5 EU/mg mean?

It is an endotoxin result from the LAL test. EU stands for endotoxin units. The less-than sign means the test found no endotoxin above 0.5 EU per milligram at the dilution used. It is a passing result below the reporting limit, not a measurement of exactly 0.5.

This guide is educational and describes laboratory analysis only. It is not use, dosing or administration guidance. G2 MEDS products are sold strictly for in-vitro laboratory research and are not for human or veterinary use.

Free shipping over $150Ships same business day (order by 3 pm ET).
Discreet, insulated packagingLyophilized vials packed with storage labeling.
Research-use termsSold for in-vitro laboratory research only.